Advantages:
Dual rotation Mitsubishi Inverter compressor, defrosting system with defrost cycle and protection in the electrical panel with soft start. - Titanium spiral heat exchanger.
- Anti-corrosion ABS plastic housing and U.V. protection.
- Stable INVERTER control system.
- COP up to 11.
- Ideal for spring - autumn operation.
- The InverBoy heat pump will help you reduce your energy bill by up to 45 per cent compared to any other ON/OFF model.
- It regulates the heating capacity according to the pool temperature. When running at a speed of 20-25 per cent, it achieves a higher COP.
Specific features:
- Stable INVERTER DC compressor.
- Total electrical protection: Through INVERTER DC, the system starts at 0 A up to a constant nominal current.
- The InverBoy supports a voltage variation between 180V and 260V. - Automatic defrosting through cycle inversion, by hot gas with 4-way valve for fast and efficient defrosting.
- Braided titanium heat exchanger: 40 per cent more efficient than standard titanium exchangers.
- LED display for controlling the heat pump.
- Wi-Fi: Control via the InverGO APP.
- Body: ABS.
Technical specifications:
- Air temperature operating range: 0 °C to 43 °C.
- Heating temperature setting range: 18 °C to 40 °C.
- Ecological refrigerant gas: R32 (32% GWP compared to R410A; 25% CO2 carbon consumption; 25% cost).
- Quieter than traditional ON/OFF systems
Pump performance: Air 27 ºC / Water 27 ºC / Humidity 80%
Description | IB07 | IB09 | IB11 | IB14 |
Power (kW) | 7.5 | 9.5 | 11 | 14 |
Medium COP at 50% speed | 8.9 | 8.8 | 9.0 | 9.0 |
Pump performance: Air 15 ºC / Water 26 ºC / Humidity 70%
Description | IB07 | IB09 | IB11 | IB14 |
Power (kW) | 5.3 | 6.6 | 7.8 | 9.8 |
Medium COP at 50% speed | 5.9 | 6.0 | 6.0 | 6.0 |
Technical features
Description | IB07 | IB09 | IB11 | IB14 |
Power |
5.3 - 7.5 kW | 6.3 - 9 kW | 7.8 - 11 kW | 9.8 - 14.2 kW |
Flow rate | 2 - 4 m3/h | 2 - 4 m3/h | 3 - 5 m3/h | 4 - 6 m3/h |
Max. pool volume | 15 - 30 | 20 - 45 | 30 - 55 | 35 - 70 |
Air temperature operating range ºC | 0 ºC a 43 ºC | 0 ºC a 43 ºC | 0 ºC a 43 ºC | 0 ºC a 43 ºC |
Power supply Voltage (V) | 230 V - Single-phase | 230 V - Single-phase | 230 V - Single-phase | 230 V - Single-phase |
Input power (kW) | 0.36 ~ 1.28 | 0.45 ~ 1.60 | 0.52 ~ 1.86 | 0.64 ~ 2.28 |
Input current (A) | 1.57 ~ 5.57 | 1.96 ~ 6.97 | 2.26 ~ 8.09 | 2.78 ~ 9.91 |
Noise impact at a distance of 10 metres from the heat pump dB (A) | 19.8 ~ 31.3 | 21.8 ~ 33.8 | 22.9 ~ 33.5 | 24.2 ~ 35 |
Hydraulic connection | PVC Ø50 (glue) | PVC Ø50 (glue) | PVC Ø50 (glue) | PVC Ø50 (glue) |