Heat pump for residential pools
- Working range: -5~43°c
- Heating range: 15~40°c
- High efficiency
- Low noise
PSL-150-0258 | PSL-150-0259 | |
Recommended pool volume (m3) |
25 | 40 |
Power supply |
220 V-240 V ~/1ph/50Hz | 220 V-240 V ~/1ph/50Hz |
Gas |
R32 | R32 |
PERFORMANCE CONDITIONS: AIR 27°C/24.3°C - WATER TEMP. INLET/OUTLET: 26°C/28°C |
||
Returned power (kW) | 6.1 | 9.2 |
Power absorbed (kW) | 1 | 1.52 |
COP | 6.1 | 6.05 |
PERFORMANCE CONDITIONS: AIR 15°C/12°C - WATER TEMP. INLET/OUTLET: 26°C |
||
Returned power (kW) | 4.52 | 6.5 |
Power absorbed (kW) | 0.97 | 1.4 |
COP | 4.65 | 4.7 |
Maximum absorbed power (kW) |
1.6 | 2.2 |
Intensity absorbed (A) | 7.4 | 10.3 |
Water flow (m3) |
2.7 | 4 |
Hydraulic connections (mm) | 50 | 50 |
Number of ventilators |
1 | 1 |
Compressor | Mitsubishi | Mitsubishi |
Exchanger |
Titanium |
Titanium |
Defrost |
Cycle reversal |
Cycle reversal |
Dimensions (mm) |
910 x 355 x 660 | 910 x 355 x 660 |
Weight (kg) | 44 | 54 |
PSL-150-0260 | PSL-150-0261 | |
Recommended pool volume (m3) |
55
|
65
|
Power supply |
220 V-240 V ~/1ph/50Hz | 220 V-240 V ~/1ph/50Hz |
Gas |
R32 | R32 |
PERFORMANCE CONDITIONS: AIR 27°C/24.3°C - WATER TEMP. INLET/OUTLET: 26°C/28°C |
||
Returned power (kW) | 12.3
|
16.2 |
Power absorbed (kW) | 2.05
|
2.7 |
COP | 6 | 6.01 |
PERFORMANCE CONDITIONS: AIR 15°C/12°C - WATER TEMP. INLET/OUTLET: 26°C |
||
Returned power (kW) | 8.57
|
10.21
|
Power absorbed (kW) | 1.8
|
2.19
|
COP | 4.7 | 4.67 |
Maximum absorbed power (kW) |
2.65
|
3.6
|
Intensity absorbed (A) | 12.4
|
16.4
|
Water flow rate (m3) | 5.3
|
7.1
|
Hydraulic connections (mm) | 50 | 50 |
Number of ventilators |
1 | 1 |
Compressor | Mitsubishi | Mitsubishi |
Exchanger |
Titanium |
Titanium |
Defrost |
Cycle reversal |
Cycle reversal |
Dimensions (mm) |
940 x 380 x 670 | 940 x 380 x 670 |
Weight (kg) | 69
|
71
|