Make the best use of your pool by extending its period of use in an environmentally friendly way. Use solar energy and increase the temperature of your pool in the months when it is already hot, but the water in your pool is still cold. The black PEHD solar panels, due to their design, allow the perfect capture of the sun and also their application in various positions. The architecture of the panels gives them the possibility of connection in the most diverse positions or alignments due to the 8 possibilities of hydraulic connections. You can choose to use the system in a manual or automatic mode, opting to install the temperature control, this last possibility being composed of a temperature control module, temperature probes, three-way valve or circulating pump. The temperature control module enables the pool pump to be activated whenever the temperature falls below the set point.
Versatile: it can be placed in a wall position, on a roof or on a flat surface.
Easy installation: to fix it, you can drill holes in the flat parts of the panel.
Technical specifications |
Panel 1,2 | Panel 2,2 |
Measures (mm) | 1,090 x 1,110 x 15 | 2,000 x 1,110 x 15 |
Usable area (m2) | 1,2 | 2,22 |
Connections |
4 de Ø 40 e 4 de Ø 25. | 4 de Ø 40 e 4 de Ø 25. |
Income |
n0 - 81,7% | k1 - 24,29 W/m2 k | n0 - 81,7% | k1 - 24,29 W/m2 k |
Flow rate (l/h per m2 panel) |
143 l/h by m2 | 143 l/h by m2 |
Loss of load |
0,003 bar a 200 l/hxm2 | 0,003 bar a 200 l/hxm2 |
Weight(Kg) | 8,5 | 14 |
Maximum pressure (bar) | 3 | 3 |
Maximum temperature (˚C) | 1,5 | 1,5 |
Minimum temperature (˚C) | 70 | 70 |
Capacity (l) | -50 | -50 |
Material / colour |
PEHD / Black | PEHD / Black |
Panels connected by Ø40 connections |
8 per row |
8 per row |
Panels connected by Ø25 connections |
Maximum 8 per column |
Maximum 4 per column |
Connection in sun exposure |
Maximum 6 columns x 8 rows |
Maximum 6 columns x 4 rows |
Installation limit heights |
10m above water level or 3m below |
10m above water level or 3m below |
REGULATOR FOR SOLAR PANEL
Entries |
4 T˚ PT1000 probes, 1 sensor |
Outputs |
1 semiconductor relay, 1 PWM output |
Frequency |
PWM: 512Hz |
Voltage |
10,5V |
Total power output |
2A 240V |
Feeding |
240 V (50 - 60 Hz) |
Consumption in standby mode |
< 1W |
Functions |
Operation control, hour meter hour meter, |
Functions |
speed control and consumption meter consumption meter |
Protection |
IP 20/ICE 60529 |
Ambient temperature |
0 - 40˚C |
Dimensions |
172 x 110 x 46 mm |
PANEL CALCULATION GUIDE
Step 1: Choose the solution that best adapts to the measurements of your pool
Step 2: Identify on the map the area where your pool is located
Step 3: Select the number of panels required according to the pool and geographical area
Pool | Zone |
Panel 1,2 | Panel 2,2 |
15 m2 | Yellow |
16 | 8 |
15 m2 | Orange |
16 | 8 |
15 m2 | Red |
8 | 4 |
30 m2 | Yellow |
32 | 16 |
30 m2 | Orange |
24 | 12 |
30 m2 | Red |
16 | 8 |
50 m2 | Yellow |
48 | 24 |
50 m2 | Orange |
32 | 16 |
50 m2 | Red |
32 | 12 |