The performances of Z300 are evaluated in a laboratory accredited by the NF certification body, something that underlines its performance and quality.
- Certified performances
- Heating guaranteed thanks to priority heating
- Possibility of installation on a technical site
Technical characteristics
- Horizontal air outlet
- Polypropylene frame
- LCD display
- Heating priority mode (filtration pump control)
- On-off control possible via remote switch or home automation system
- Automatic defrosting (forced ventilation)
- Titanium heat exchanger, compatible with salt water treatment
- On-off compressor, rotary
Accessories included
- Protective cover
- Drain kit
- PVC couplings, 1/2 couplings, Ø 50
- Anti-vibration feet
Z300 M4 | Z300 M5 | Z300 T5 | Z300 M7 | |
POWER SUPPLIED* |
9 | 13 | 13,1 | 16,1 |
POWER ABSORBED |
1,6 | 2,4 | 2,3 | 2,9 |
COP | 5,6 | 5,5 | 5,6 | 5,6 |
Z300 M4 | Z300 M5 | Z300 T5 | Z300 M7 | |
POWER SUPPLIED - kW |
7,6 | 10,4 | 10,5 | 13,7 |
ABSORVED POWER - kW |
1,7 | 22 | 22 | 2,9 |
COP | 4,5 | 4,7 | 4,7 | 4,7 |
RECOMMENDED AVERAGE FLOW - m3 / h |
4 | 5 | 5 | 6 |
HYDRAULIC FEED |
PVC ½ racords, ø 40 or ø 50 , for gluing |
PVC ½ racords, ø 40 or ø 50 , for gluing |
PVC ½ racords, ø 40 or ø 50 , for gluing |
PVC ½ racords, ø 40 or ø 50 , for gluing |
POWER SUPPLY |
220-240V / 1 N~ / 50Hz | 220-240V / 1 N~ / 50Hz | 380-400V / 3N~ / 50Hz | 220-240V / 1 N~ / 50Hz |
NOMINAL INTENSITY ABSORBED - A |
7,9 | 10,3 | 4,3 | 13 |
MAXIMUM INTENSITY ABSORBED - A |
10 | 14,5 | 5,3 | 16,4 |
RECOMMENDED MAINS CABLE SIZE* |
3 x 25 | 3 x 25 | 5 x 25 | 3 x 4 |
COOLING FLUID |
R410A | R410A | R410A | R410A |
QUANT. COOLING FLUID - Kg |
0,92 | 1,55 | 1,55 | 1,4 |
ACUSTIC POWER - m3 / h |
67 | 68 | 70 | 67 |
ACOUSTIC PRESSURE AT 10M** - dB (A) |
36 | 37 | 39 | 36 |
Weight (Kg) | 52 | 63 | 63 | 68 |
*Cable not included. Section recommended for a maximum length of 20 metres.
**Complies with EN60704-1:2010+A11:2012 standard