The Zodiac® PI20 is a heat pump that combines design and performance, ideal for heating small pools. The dimensions of this heat pump have been minimised so that it takes up minimal space in your garden. As the basic Zodiac® model, it is super economical and incorporates all the manufacturer's experience and technical expertise to achieve impressive performance in its class.
M4 | M5 | |
Operating temperatures Air | de 5 a 32°C | de 5 a 32°C |
Operating temperatures Water | até 32°C | até 32°C |
Returned power* (kW) | 8,1 | 10,1 |
Supply voltage | 220-240 V / 50Hz | 220-240 V / 50Hz |
Forced ventilation defrost | X | X |
Acceptable voltage variation | -10%, +7% (during operation) | -10%, +7% (during operation) |
Nominal absorbed intensity (A) | 7,9 | 11,2 |
Maximum absorbed intensity (A) | 10,2 | 13,4 |
Minimum cable section** (mm2) | 3x2,5 | 3x2,5 |
3G2,5 | 3G2,5 | |
Test pressure (bar) | 6 | 6 |
Operating pressure (bar) | 1,5 | 1,5 |
Max. discharge/suction pressure (bar) | 42/1,2 | 42/1,2 |
Max. side pressure high pressure/low pressure (bar) | 42/1,2 | 42/1,2 |
Load loss (mCE) | 1,5 | 1,5 |
Minimum optimum water flow (m3/h) | 4 | 4 |
Maximum water flow (m3/h) | 10 | 10 |
Type of refrigerant | R32 | R32 |
Refrigerant charge | 0,9 | 1,1 |
Weight (Kg) | 46 | 51 |
The devices have an IP rating of IPX4 or higher. Please refer to the label indicating the IP rating on your product.
* Performances: air at 15 °C / water at 26 °C / humidity at 70%.
** Values given as an indication for a maximum length of 20 metres (calculation basis: NFC 15-100), must be checked and adapted according to the installation conditions and standards of the country of installation.